Automated Nucleic Acid Extraction - NAE100132

In stock: 4
Product Information Product code : NAE100132 NAE100132 is a high-throughput nucleic acid extractor that uses magnetic bead technology to purify DNA and RNA from a wide range of sample types. The system features a user-friendly interface that allows for easy programming of extraction parameters and the ability to process up to 32 samples in a single run. With its advanced magnetic bead technology and multiple heating modules with individual heating controls, the NAE100132 delivers high yields of pure nucleic acid with minimal hands-on time, reducing the risk of contamination and ensuring reliable results. The system is suitable for use in both research and clinical settings, making it an ideal solution for high-throughput nucleic acid extraction needs.

How it works

Prep & Transfer

Prepare samples by adding lysis buffer and bead solution as appropriate to sample and homogenize it into the 96-well plate.

Start Extraction

Using the touchscreen interface, program the incubation temperature, duration, and agitation speed. The extractor will automatically with extraction, including magnetic bead capture, washing, and elution.

Collect Nucleic Acid

Once extraction is complete, the system will dispense purified nucleic acid into a clean, new 96-well plate, ready for downstream analysis.

Automated Nucleic Acid Extraction - NAE100132

We’re Serving Laboratory Market Worldwide

At 4E's, we ensure quality by implementing rigorous testing and inspection protocols on our products, which allows us to deliver reliable laboratory equipment to our customers. Our knowledgeable and responsive support team provides excellent customer assistance, ensuring that our customers receive the best possible experience when working with us.

10,000+

Customers

3,000+

Answered calls

5,000+

Emails answered

Specification

Volume Capacity 30-1000μl
Sample Quantities 1-32
Plate Quantity 2
Plate Type 96-well deep-well plate
Processing Time 20min-40min/run (depending on reagent types/volumes)
Reagent Type Magnetic bead-based open-source reagents
Heating Temp Room Temp.~ 100℃
Mixing Intensities Adjustable | 5 Levels
Magnetic Bead Recovery Rate 96%
Inter-well Purification Variation CV<5%
Working Noise <50dB
Exhaust Fan
Data Storage Capacity >500 programs
Program Management Create, Edit, and Delete options available
High-throughput Processing
Magnetic Bead Technology
User-friendly Interface

High-throughput Processing

NAE100132 can process up to 32 samples in a single run, allowing for high-throughput extraction of nucleic acid.

Magnetic Bead Technology

The use of magnetic beads allows for efficient and selective capture of nucleic acid, resulting in high yields of pure DNA or RNA.

User-friendly Interface

The touchscreen interface is easy to navigate and allows for quick and simple programming of extraction parameters.

High-throughput Processing Magnetic Bead Technology User-friendly Interface
High-throughput Processing High-throughput Processing
Magnetic Bead Technology Magnetic Bead Technology
User-friendly Interface User-friendly Interface

High-throughput Processing

NAE100132 can process up to 32 samples in a single run, allowing for high-throughput extraction of nucleic acid.

Magnetic Bead Technology

The use of magnetic beads allows for efficient and selective capture of nucleic acid, resulting in high yields of pure DNA or RNA.

User-friendly Interface

The touchscreen interface is easy to navigate and allows for quick and simple programming of extraction parameters.

High-throughput Processing Magnetic Bead Technology User-friendly Interface

Advanced heating control

The system includes multiple heating modules with individual temperature control to ensure optimal temperature accuracy during lysis and elution steps. This allows for precise temperature control and eliminates the risk of overheating or underheating during the extraction process, which can lead to degradation of nucleic acid and poor results.

Minimal Hands-On Time

The NAE100132 is fully automated, reducing the need for manual intervention and minimizing the risk of contamination. This allows for reliable and reproducible results, even when processing large numbers of samples. The system also has an auto-check function that ensures the correct positioning of the 96-well plate and magnetic rods, further reducing the risk of errors.

Compact Design

The NAE100132 has a small footprint, making it ideal for use in laboratories with limited bench space. The system is also easy to set up and use, requiring minimal maintenance and no special infrastructure or installation. Its compact design and ease of use make it an attractive option for labs with limited resources or space.

Frequently Asked Questions

Everything you need to know about product and billing. Can’t find the answer you are looking for? Please write your question to us at info@4Es-USA.com

How many samples can I run on the device at once?

4E’s Gradient PCR Optima 96 can run 96 samples at once with 6 individual heating blocks to provide precise temperature control and PCR optimization.

Can the device accommodate different types of PCR tubes, strips, and plates?

Optima 96 accommodates for all different types of PCR tubes, strips, and plates, making it ideal for a wide range of PCR applications, including but not limited to gene expression analysis, DNA sequencing, mutation detection, and cloning.

Is there warranty of this device?

Yes, we have a two-year warranty on our Gradient PCR devices.

Can Optima 96 save user profiles and experiments for future use?

Yes, the Optima 96 has multiple accounts and access rights, which includes the ability to save user profiles and experiments for future use.